Anodizing Plant Division

Pulse Rectifier

Advantages of using pulse rectifiers in anodizing

With the use of pulse rectifiers, the oxide quality is better than the one obtained with a conventional rectifier, as proved by the tests on abrasion, efficiency (ISO 321 O) and corrosion (Kestern ich).

So it is possible (without disadvantages) to work with a current density higher than conventional rectifiers. Thus the use of pulse rectifiers gives a benefit of 20- 25% time saving compared with the conventional ones.

 

CHOICE OF CURRENT VALUE (AMPERE)

The pulse rectifiers are characterized by 3 values.

— Base current

— Pulse current = base current x 1,5

— Average current = 1,35 x base current

Example:

– Base current = 2000 A

– Pulse current = 2000 x 1,5 = 3000 A

– Average current = 2000 x 1,35 = 2700 A

Therefore:

lf the size of a pulse rectifier is chosen with the same average current of a conventional rectifier a better oxide quality is obtained, but without any time saving.

lf the size is chosen with the same base cur­- rent as a conventional rectifier, also a 20 – 25% time saving is obtained.

MAX. VOLTAGE

The pulse rectifiers are provided for a 22 V max. voltage (instead of 20V max. as for conventional rectifiers) to have the possibi­lity of pulse superposing.

TECHNICAL FEATURES

Control:

By means of SCR set on primary or secondary side

Rectifier circuit:

Six-phase provided with interphase transformer.

Main transformer: according to IEC 742 standard “Safety isolating transformers”

General switch:

Magnetothermic or magnetic (automatic) type

Cooling:

Air cooling: by means of ventilator and air filters (max. ambient temperature: 45°C. Protection IP20.

On request: closed loop air cooling by means of air/water exchanger (IP54)

 

 

Protections:

  • Max. current: by means of electronic device and automatic general switch
  • Max. temperature: by means of thermo­stats inside the main transformer win­dings and on the diode cases.

Voltage/current control:

Constant current and (or) constant voltage control

Accuracy ± 1 o/o against ± 10% network variation and load variation from 10% to 100%.

Optionals:

  • lnterfacing with external PLC (by means of opto- insulated cards)
  • APC -Anodizing process computer:
  • Automatic survey of the surface to be anodized
  • Pre-setting of anodizing current density
  • Pre-setting of the requested number of microns

Automatic printout of anodizing parame­ters. Further technical details in our bro­chure “APC”-Anodizing Process Computer.

Feel free to ask to our commercial department
service@italtecno.com